home *** CD-ROM | disk | FTP | other *** search
- Path: bloom-beacon.mit.edu!hookup!swrinde!emory!news-feed-2.peachnet.edu!concert!bigblue.oit.unc.edu!sunSITE!mdw
- From: terryd@extro.ucc.su.oz.au (Terry Dawson)
- Newsgroups: comp.os.linux.announce,comp.os.linux.help,comp.os.linux.admin,news.answers,comp.answers
- Subject: Linux NET-2 HOWTO
- Followup-To: poster
- Date: 16 Mar 1994 05:27:32 GMT
- Organization: The University of North Carolina at Chapel Hill
- Lines: 2148
- Approved: linux-announce@tc.cornell.edu (Matt Welsh)
- Message-ID: <2m65c4$e16@bigblue.oit.unc.edu>
- NNTP-Posting-Host: calzone.oit.unc.edu
- Summary: HOWTO configure TCP/IP networking, SLIP, PLIP, and PPP under Linux.
- Keywords: Linux, Networking, TCP/IP, NET-2, SLIP
- Originator: mdw@sunSITE
- Xref: bloom-beacon.mit.edu comp.os.linux.announce:1954 comp.os.linux.help:26197 comp.os.linux.admin:5615 news.answers:16453 comp.answers:4184
-
- Archive-name: linux/howto/networking
- Last-modified: 21 Feb 94
-
- This is the Linux NET-2 HOWTO (previously known as the NET-2-FAQ).
- This document explains how to configure TCP/IP and SLIP with the new
- ``NET-2'' networking code in Linux kernels 0.99.pl10 and above.
- Please mail me if you have questions or comments. --terryd
-
- This is the Linux NET-2 HOWTO v1.11, 26 January 1994
- By Terry Dawson <terryd@extro.ucc.su.oz.au> and
- Matt Welsh <mdw@sunsite.unc.edu>
-
- (c)1994 by Terry Dawson, Matt Welsh
-
- CHANGES from previous version:
- Added the NFS questions and answers that Alan posted, thanks Alan.
- Added dynamic slip server script - thanks Paul Mossip!
- Added dip-i source, thanks Karl, kkeyte@esoc.bitnet
- Added copyright message. Ack.
-
- *** FTP site maintainers: This document should be stored in the docs/HOWTO
- *** directory on your Linux archive as ``NET-2-HOWTO''. You may also wish
- *** to link this file to ``NET-2-FAQ'' (its previous name). This document
- *** also supercedes the old Linux NET-FAQ.
-
- 'Real Programmers don't write documentation.' -- Ancient Proverb
-
- INDEX for this version
-
- To search for a particular section, search for '^N.S' where
- N is the section, and S is the Subsection.
-
- 0. Introduction.
- 0.1 Disclaimer.
- 0.2 Questions already ?
- 0.3 Related documentation.
- 0.4 New versions of this document.
- 0.5 Feedback.
- 1. NET-2 Supported Functionality.
- 1.1 Supported Ethernet cards.
- 2. Getting the NET-2 Software.
- 2.1 Unpacking the software.
- 2.2 Putting things in the right place.
- 2.3 Creating the device interfaces.
- 3. Building the Kernel.
- 3.1 Configuring the NET-2 kernel code.
- 3.2 Building the kernel.
- 4. Configuring NET-2 TCP/IP.
- 4.1 Before you begin.
- 4.2 /etc/rc.d/rc.inet1 and /etc/rc.d/rc.inet2
- 4.2.1 Editing rc.inet1
- 4.2.2 Editing rc.inet2
- 4.2.2.1 "To named or not to named... that is the question."
- 4.3 /etc/hosts
- 4.3.1 Important note regarding /etc/hosts from NET-032.
- 4.4 /etc/networks
- 4.5 /etc/host.conf
- 4.6 /etc/resolv.conf
- 4.7 /etc/HOSTNAME
- 4.8 /etc/rc.local
- 4.9 Other files.
- 5. Configuring SLIP.
- 5.1 Static SLIP server connections using a dialup line.
- 5.2 Static SLIP server connections using a leased line or cable.
- 5.3 Dynamic SLIP server connections using a dialup line.
- 5.4 Using DIP.
- 5.5 Configuring your Linux Machine as a SLIP Server.
- 5.6 /etc/net/diphosts
- 5.7 Configuring PLIP interfaces.
- 5.7.1 PLIP Cabling Diagram.
- 6. PPP (Under construction).
- 7. AX.25 (Under construction).
- 8. Are You Stuck ?
- 9. Common Problems and Solutions.
- 9.1 Not so common problems and solutions (Mostly NFS).
- 10. Known bugs.
- 11. Copyright Message. (We're not ogres, nor are we silly).
- 12. Miscellaneous.
- 13. Change History.
-
- ------------------------------------------------------------------------------
- 0. Introduction.
-
- This is the NET-2 HOWTO, which is a rewrite of the earlier NET-FAQ for
- the new NET-2 TCP/IP code in Linux kernels 0.99.pl10 and above.
-
- The NET-2 code is the new kernel-based networking support for Linux,
- written by Fred van Kempen <waltje@uwalt.nl.mugnet.org>. It is based
- on the NET-1 code by Ross Biro <bir7@leland.stanford.edu>, ethernet
- drivers by Donald Becker <becker@super.org>, SLIP drivers by
- Laurence Culhane <loz@holmes.demon.co.uk>, and the D-Link driver by
- Bj0rn Ekwall <bj0rn@blox.se>. The NET-2debugged code is maintained
- by Alan Cox <iiitac@pyr.swan.ac.uk>. Many others too numerous to
- mention have provided support, bug fixes, and help.
-
- This NET-2 HOWTO is by Terry Dawson and Matt Welsh. It covers setup
- and configuration of TCP/IP under Linux using NET-2. It also hopefully
- answers some of the many questions about the NET-2 code and common
- problems that people have. It does not cover using TCP/IP (i.e.
- using telnet, FTP, etc.), other documents are available which will
- describe these much better than I am able to.
-
- 0.1 Disclaimer.
-
- The NET-2 code is under development, which means that it may
- not be as stable and easy to configure as you may like it to be.
- code is relatively new and bug fixes are being posted every day, so if
- you run into a large number of problems just hang in there. The
- software is in two stages of development at the moment. The version
- currently supplied in the standard kernel distribution is version
- NET-2D(ebugged), and is being progressively debugged and made more
- stable by Alan Cox, until NET-2E, which is currently undergoing Beta
- testing, is ready for general release.
-
- We do not, and cannot know everything there is to know about the
- Linux networking code. Please accept that this document may, and
- probably does contain errors. Please read any README files that
- are bundled with any of the various pieces of software described
- in this document for more detailed and accurate information. We
- will attempt to keep this document as error free as possible.
-
- NOTE: In this document, 'NET-2' does not refer to the Berkeley
- Software Distribution NET-2 release of BSD UNIX. Yes, the names
- are conflicting. In this HOWTO, 'NET-2' refers only to the new
- generation of TCP/IP code in the Linux kernel.
-
- 0.2 Questions already ?
-
- 'The only stupid question is the unasked one.' - One of my own Motto's
-
- If you have general configuration questions, and you have been unable
- to find the answers after reading the other various HOWTO and FAQ
- files, then you would be best served to post them comp.os.linux.help,
- or, if you believe it to be specifically related the NET-2 kernel
- code, then you could post it to the NET mailing list. Please include
- as much relevant information as possible, there is nothing more
- annoying than to have a bug or problem reported without sufficient
- information to even begin searching for it.
-
- Version numbers and revisons of code, a detailed account of the
- problem, and the circumstances that caused it to happen are essential.
- Traces and debug messages where available should also be considered
- mandatory.
-
- If you have a question relating to the configuration of, or problems
- experienced with, _any_ linux distribution, regardless of
- whether it be SLS, Slackware, Yggadsril, TAMU, MCC, Pro, or other,
- please contact the people who created the distribution for support
- before attempting to report it to the list or the NET-2 developers
- directly. The developers of the NET-2 code _cannot_ and _will not_
- offer support for NET-2 as distributed in any form, other than as
- specified in this document, or as per distributed Alpha/Beta test
- instructions.
-
- Please do NOT bug the NET-2 developers directly unless you have a
- _development_-related issue (especially Fred: he has to pay $$$ for
- his e-mail access).
-
- To join the NET channel of the Linux-activists mailing list
- send mail to
- linux-activists-request@niksula.hut.fi
- with the line
- X-Mn-Admin: join NET
- at the top of the message body (not the subject).
-
- Note that the SLIP channel of the mailing list has been disabled and
- the NET channel should be used for SLIP discussions as well.
- Remember, keep in mind that the NET channel is for development
- discussions only.
-
- Note also that a PPP list has been established. To join it, use the
- same procedure as for joining the NET list, except specify PPP in
- place of NET.
-
-
- 0.3 Related documentation.
-
- There is now a book from the Linux Documentation Project entitled
- `Linux Network Administration Guide' by Olaf Kirch. It covers all
- aspects of setting up and using networking under Linux, including
- TCP/IP, NFS, UUCP, mail, news, etc.
-
- This book supplements the NET-2 HOWTO and covers all of the
- other aspects of using TCP/IP. This guide simply covers setup of
- NET-2, i.e., "How to put your machine on the net". If you are new
- to unix networking, then I strongly urge you to obtain a copy and
- read it first. It will answer a lot of questions for you that are
- not within the scope of this document.
-
- The current version is available in:
-
- sunsite.unc.edu:/pub/Linux/docs/linux-doc-project/network-guide
-
- There are various versions of the file available. The most common
- formats are supported, being plain ascii, Postscript, DVI, Latex
- and groff.
-
- The Linux Network Administrators Guide is Copyright (c) by Olaf Kirch.
-
- You should read the Ethernet HOWTO (from sunsite.unc.edu:
- /pub/Linux/docs/HOWTO) if you are using an Ethernet network
- with NET-2. The Ethernet HOWTO explains all of the ins and outs
- of using and configuring Ethernet devices for Linux, and should
- be considered the definitive source of information relating to same.
- That is, if the Ethernet HOWTO and this HOWTO differ, then believe
- the Ethernet HOWTO.
-
- This NET-2 HOWTO supercedes the earlier 'Linux NET-FAQ' by Phil
- Copeland and Matt Welsh. The NET-FAQ is for Linux kernels previous
- to 0.99.pl10, running the older version of the TCP/IP code.
-
- This document used to be called the NET-2-FAQ, before the Linux HOWTO
- project was underway. Thus, the NET-2-FAQ and the NET-2 HOWTO are
- the same.
-
- 0.4 New versions of this document.
-
- New versions of this document can be retrieved via anonymous
- FTP from sunsite.unc.edu:/pub/Linux/docs/HOWTO/NET-2-HOWTO
- or directly from me (terryd@extro.ucc.su.oz.au). It will also be
- posted to the newsgroups comp.os.linux.announce, comp.os.linux.help,
- and news.answers periodically.
-
- You can find news.answers FAQ postings, including this one, archived
- on rtfm.mit.edu:/pub/usenet.
-
- 0.5 Feedback.
-
- Please send any comments, updates, or suggestions to me,
- terryd@extro.ucc.su.oz.au. The sooner I get feedback about this
- document, the sooner I can update and correct it. If you find any
- problems with it, please mail me, instead of posting to one of the
- newsgroups. I may miss your corrections. Thanks.
-
- Please send any money or interesting pieces of hardware to either
- Fred, Linus, or the Free Software Foundation. They made this happen.
-
-
- 1. NET-2 Supported Functionality.
-
- The NET-2 code is a complete kernel implementation of TCP/IP for
- Linux, including many features not found in the original networking
- code. NET-2 supports most popular Ethernet cards, real IP routing,
- SLIP (Serial Line IP) for TCP/IP connections over a serial line, such
- as the phone line via modem, and PLIP (Parallel Line IP) for local
- connection of two machines using your printer ports.
-
- NET-2 does not yet include:
-
- - SPX(SPP)/IPX(IDP)/NCP support, though it is being worked on.
- - PPP support, this is being worked on, and an ALPHA version exists.
- read on for more details.
- - AX.25 support natively, though Alan Cox has some experimental code
- available for pl14+ for you to try. Fred has the start of fully
- integrated DDI based AX25 support in NET-2EB2+
- - LAN types other than Ethernet, this means no Token Ring, no
- FDDI, no ARCNET, etc. An experimental Token Ring driver is being
- quietly developed.
- - ISDN support, though I understand it too is being worked on.
-
- 1.1 Supported Ethernet cards.
-
- NET-2 supports the following Ethernet cards (and more):
-
- 3com 3c503, 3c503/16
- Novell NE1000, NE2000
- Western Digital WD8003, WD8013
- Hewlett Packard HP27245, HP27247, HP27250
-
- The following clones are reported to work:
- WD-80x3 clones: LANNET LEC-45
- NE2000 clones: Alta Combo, Artisoft LANtastic AE-2, Asante Etherpak
- 2001/2003, D-Link Ethernet II, LTC E-NET/16 P/N 8300-200-002,
- Network Solutions HE-203, SVEC 4 Dimension Ethernet, 4-Dimension
- FD0490 EtherBoard 16, D-Link DE-600, SMC Elite 16.
-
- ** Please see the Ethernet HOWTO for more complete information. **
-
- As mentioned above, NET-2 also supports SLIP in the kernel. Therefore
- if you don't have an Ethernet connection you can do TCP/IP over the
- phone line, provided you have a SLIP server nearby (many universities
- and businesses provide SLIP access to employees/students) and a
- compatible modem (usually 14.4 v.42bis, depending on your SLIP server).
- Two possible modems are the US Robotics Sportster, or the Infotel
- 144DF Internal.
-
-
- 2. Getting the NET-2 Software.
-
- Before you can configure TCP/IP on your system you need to get the
- appropriate software. This includes the current version of the Linux
- kernel (0.99.pl14 or above), TCP/IP configuration programs and files
- (e.g., /etc/ifconfig, /etc/hosts), and finally a set of network
- application programs (such as telnet, ftp, rlogin, etc.).
-
- You may already have all of the items below. Check and make
- sure that you do. For example, some distributions come with all
- of the NET-2 configuration files, binaries, libraries, and kernel
- installed, so there's no reason to get the following files.
- Note: they may not be in the places specified in this HOWTO.
-
- If you DO have the NET-2 software already, skip to section 3 on
- configuration. If you do NOT have the NET-2 software, follow the
- directions below.
-
- The current kernel version is found in
- nic.funet.fi:/pub/OS/Linux/PEOPLE/Linus/linux-0.99.14.tar.gz.
- This is a gzipped tar file; .gz is the new extension used by gzip.
- If you have the old version of gzip, "zcat foo.gz | tar xvf -" works.
-
- The current libraries (libc-4.4.4), can be found in
- sunsite.unc.edu:/pub/Linux/GCC/image-4.4.4.tar.z. (You'll probably
- want to install the include files in inc-4.4.4.tar.z as well! See the
- READMEs there for details.) You'll need at least ver 4.4.2 to use
- NET-2, as there were problems with earlier versions that affected
- routing and netmasks.
-
- The current NET-2 configuration file distribution is in
-
- sunacm.swan.ac.uk:
- /pub/misc/Linux/Networking/Programs/System/net032/net-0.32.tar.gz
-
- This package includes network configuration programs such as
- ifconfig, route, netstat etc.
-
- The TCP/IP application binaries and setup files are found in:
-
- tsx-11.mit.edu:/pub/linux/packages/net/net-2/binaries/net-base.tar.z
- " " " " " " " /net-std.tar.z
- " " " " " " " /net-ext.tar.z
-
- As some of the internals of the networking code have changed, you will
- also need to get and install the files that are in the:
-
- tsx-11.mit.edu:/pub/linux/packages/net/new-net-2
-
- directory, as they correct some problems you will experience if you
- opt _not_ to get and install them :)
-
- If you use shadowed password (Most SLS users do), then you may find
- that the standard network programs do not support them. There used
- to be a specially modified package of binaries about, but these were
- intended as a short term fix, and have been removed. Recent work on
- the standard libraries will mean that as of version 4.5.8 of libc,
- the shadow password handling will no longer need to be in the
- application, and will be handled externally. At the time of writing
- libc.4.5.8 has just been released. If you use shadowed passwords
- you will most certainly want a copy of this.
-
- 2.1 Unpacking the software.
-
- You don't need to unpack any of the following if you already have all
- of the NET-2 software installed.
-
- First, unpack the kernel sources in /usr/src. This will put all
- of the kernel sources under /usr/src/linux (the usual place).
-
- # cd /usr/src
- # zcat linux-0.99.14.tar.z | tar xvf -
-
- Next, unpack the libraries.
- (The following is a summary, please read the detailed instructions
- that come with the libraries for complete installation details)
-
- # cd /
- # zcat image-4.4.4.tar.z | tar xvf -
-
- Now, make the links to the new libraries in /lib. BE VERY CAREFUL
- that you do not delete the previous links. Do everything in
- one step, as so:
-
- # ln -sf /lib/libc.so.4.4.4 /lib/libc.so.4
- # ln -sf /lib/libm.so.4.4.4 /lib/libm.so.4
-
- Next, unpack the net-base package, which contains the basic
- utils and configuration files in /etc. Note that net-base makes
- symlinks in /etc for all of your TCP/IP configuration files to /conf.
-
- Therefore, BE WARNED: Before you unpack the following tar files,
- make a backup of your files in /etc. Unpacking net-base will overwrite
- many of the files in /etc with symbolic links to other places.
- For example, /etc/hosts is a symlink to /conf/net/hosts. Why is this
- done? Because Fred's Linux/PRO distribution of Linux keeps all
- machine-specific configuration files in /conf. And because this is
- the way he does it, we may as well too. In general it makes things
- easier to locate. If you want to keep all of your net files in
- /etc, that's fine, but you'll have to put them there by hand.
-
- Make a backup of everything in /etc before you unpack net-base.
- Then unpack it from / (the root directory):
-
- # cd /
- # zcat net-base.tar.z | tar xvvofp -
-
- Also, unpack net-std.tar.z, which contains the network clients and
- daemons (e.g., telnet and telnetd). Unpack it from / as well:
-
- # cd /
- # zcat net-std.tar.z | tar xvvofp -
-
-
- If you wish to use tin (a newsreader), or DIG (the DARPA Internet
- Groper), unpack the net-ext package from /:
-
- # cd /
- # zcat net-ext.tar.z | tar xvvofp -
-
- Now unpack the fixed versions of rlogin/telnetd from the files:
-
- # cd /tmp
- # gzip -dc ftpd.tar.z | tar xvf -
- # gzip -dc telnet-rlogin.tar.z | tar xvf -
-
- you will then need to copy the binaries to where the old
- version currently live.
-
- Finally, unpack the net-032 package, which contains the sources
- for the TCP/IP setup programs (ifconfig, arp, route, etc.) and the
- configuration files. This is unpacked into /usr/src/net-032.
-
- # mkdir /usr/src/net-032
- # cd /usr/src/net-032
- # zcat net-032.tar.gz | tar xvvofp -
- # make install
-
- ** Important information for Shadow Password users **
- If you are using the SLS distribution, then replace any blank
- passwords in /etc/passwd with :x: instead of ::.
- Otherwise rshd/rlogind will let anyone become these user ids.
- This is an SLS setup bug and will, by default allow anyone remote
- access to your machine, with root priveledges!
-
- 2.2 Putting things in the right place.
-
- With the standard NET-2 distribution, all of the configuration files
- are in /conf/net, with links in /etc. For example, /etc/hosts
- is a link to /conf/net/hosts. However, if you are using a
- standard pre-packaged distribution of Linux such as SLS, /conf/net
- probably isn't used... that is, /etc/hosts is just /etc/hosts.
- So, when I say "/conf/net/hosts", I mean "/etc/hosts", and vice
- versa.
-
- Just keep in mind that the TCP/IP software only looks in /etc and
- /usr/etc for configuration files. Therefore, it makes sense to
- keep all of your files in /etc and /usr/etc as they should be.
- HOWEVER, Fred has decided to put the files in /conf/net with LINKS
- in /etc. Either way, it doesn't matter. When we say "/etc/hosts",
- it doesn't matter if /etc/hosts is an actual file or a link to
- /conf/net/hosts.
-
- If you just unpacked NET-2 above (i.e. you don't already have the
- files from installing SLS), then you don't have the configuration
- files in /conf/net (you only have the symlinks in /etc).
- The easiest way to get the configuration files in /conf/net is
- to copy them from the net-032 distribution:
-
- # mkdir -p /conf/net
- # chown -R root.root /conf; chmod -R 755 /conf
- # cp /usr/src/net-032/etc/* /conf/net
-
- You should make sure that all of the symlinks to /conf/net in /etc
- can be resolved (that is, try to "more" or "cat" each file, make
- sure you don't get any errors). Also note that some files will
- be duplicated: for example, /etc/inetd.conf is a symlink to
- /usr/etc/inetd.conf. However, from the cp command above you also
- have a /conf/net/inetd.conf, which can be deleted (remember that
- all of the programs still look in /etc, not /conf. So whatever is
- in /etc is the file which is actually being used).
-
-
- 2.3 Creating the device interfaces.
-
- In previous versions it was necessary to create a number of
- device files for the NET-2 code. This is no longer the case.
-
- If you have any of the following files created you should delete
- them:
-
- rm /dev/net /dev/unix /dev/inet
- rm /dev/ip /dev/icmp /dev/tcp /dev/udp
- rm /dev/wd0 /dev/wd1 /dev/wd2 /dev/wd3
- rm /dev/ec0 /dev/ec1 /dev/ec2 /dev/ec3
- rm /dev/ne0 /dev/ne1 /dev/ne2 /dev/ne3
-
- should clean them all.
-
- However, the arp program does need /dev/arp, so:
-
- mknod -m 600 /dev/arp c 16 1
-
- will create it ok. If you already have it, check that it looks
- the same.
-
- 3. Building the Kernel.
-
- You're now ready to build the new 0.99.pl14 kernel with the NET-2
- code enabled.
-
- 3.1 Configuring the NET-2 kernel code.
-
- A 'make config' will take you through configuring the kernel
- Select the drivers you desire by answering 'yes' when prompted.
-
- Note, you will be prompted for "Network Device Support?", but
- the label after it might suggest that this is for Ethernet only,
- this is not the case, and you must answer 'yes' to this, even if
- you only desire the slip or plip drivers to be configured.
- You will be asked later about each of the ethernet drivers,
- slip and plip in turn.
-
- The Ethernet HOWTO also contains much useful information for
- configuring Ethernet devices in the kernel.
-
- 3.2 Building the kernel.
-
- You can now build the kernel as you normally would (see the file
- /usr/src/linux/README if you've never done this before). Essentially
- this entails editing /usr/src/linux/Makefile to set root device and
- default display mode. (*Note: keyboard is now handled by loadable
- keymaps as of 0.99.pl10; grab the file keytable.tar.z from your
- nearest Linux ftp site).
-
- Finally do 'make dep' and 'make'. You now have a new 0.99.14 kernel
- with NET-2 set up. I wouldn't reboot it quite yet as we still have
- to configure the NET-2 programs before it will work correctly.
-
- 4. Configuring NET-2 TCP/IP.
-
- The final step is to modify the various setup files to get NET-2
- working. After this is ready you can boot your new kernel and
- go happily netting (if all goes well).
-
- In this section I'll describe each of the major TCP/IP setup files,
- what they do, and what you need to do to configure them.
-
- If you're using SLIP, see section 5.0 on configuring SLIP. The
- discussion below is for Ethernet connections only. SLIP users
- should FIRST read all of section 4.0 and then apply the changes
- discussed in section 5.0.
-
- 4.1 Before you begin.
-
- Before you can configure NET-2 TCP/IP, you need to find out
- the following information about your network setup. Your network
- admins can tell you most of these things.
-
- * IP address: this is the unique machine address in dotted-decimal
- format. An example is 128.253.153.54. Your network admins will
- provide you with this number.
-
- If you're only configuring loopback mode (i.e. no SLIP, no ethernet
- card, just TCP/IP connections to your own machine---called
- "loopback") then your IP address is 127.0.0.1.
-
- * Your network mask ('netmask'). For performance reasons, it is
- desirable to limit the number of hosts on any particular segment
- of a network. If you have a large number of addresses allocated
- to you, you might break those addresses up into large chunks,
- and create subnetworks, and then allow each individual network
- segment be a subnetwork of the whole network. The network mask
- is a pattern of bits, which when overlayed onto an address on your
- network, will tell you which subnet that address lives on. This is
- very important for routing, and if you find, for example, that you
- can happily talk to people outside your network, but not to some
- people within your network, there is a good chance that you have
- an incorrect mask specified.
-
- Your network administrators will have chosen the netmask when the
- network was designed, and therefore they should be able to supply
- you with the correct mask to use. Most networks are class C
- subnetworks which use 255.255.255.0 as their netmask. Other Class B
- networks use 255.255.0.0. The NET-2 code will automatically select
- a mask that assumes no subnetting as a default if you do not specify
- a mask.
-
- The masks chosen by default are as follows:
-
- For addresses with the first byte:
- 1-127 255.0.0.0 (Class A)
- 128-191 255.255.0.0 (Class B)
- 192+ 255.255.255.0 (Class C+)
-
- If one of these doesn't work, try the other. If this
- doesn't work, ask your local net guru for help.
-
- This applies equally well to the loopback port. Since the
- loopback ports address is always 127.0.0.1, the netmask for
- this port is always 255.0.0.0. You can either specify this
- explicitly or rely on the default mask.
-
- * Your network address. This is your IP address masked with the netmask.
- For example, if your netmask is 255.255.255.0, and your IP address
- is 128.253.154.32, your network number (IP addr AND netmask) is
- 128.253.154.0. With a netmask of 255.255.0.0,
- this would be 128.253.0.0.
-
- If you're only using loopback, you don't have a net address.
-
- * Your broadcast address. This is your IP address masked with the
- netmask, and then possibly ORed with the subnetmask inverted.
- Such that for a Class C network, with netmask 255.255.255.0,
- your broadcast address will be your network address (calculated
- above) ORed with 0.0.0.255.
-
- For example:
-
- Your IP address is: 128.253.154.32
- Your netmask is: 255.255.255.0
- netmask inverted is: 000.000.000.255
-
- then:
-
- Your broadcast address should be: 128.253.154.255.
-
- Note that for historical reasons, some networks are setup to use
- the network address as the broadcast address, if you have any doubt,
- check with your net admin.
-
- If you have access to a sniffer, or some other device capable of
- providing a trace of your network, then you might be able to
- determine both the network and broadcast addresses by looking at the
- traffic on your network. Keep an eye open (or filter all traffic
- except) for ethernet frames destined for the ethernet broadcast
- address: ff:ff:ff:ff:ff:ff, if it is an IP datagram, then look at
- the destination ip address. If the IP source address is your router,
- and the protocol ID is not ARP, then what you are seeing might be a
- routing broadcast. The destination IP address in this case will be
- the IP broadcast address of your network. You can then work out the
- IP network address. But again, if in doubt then consult your network
- admin, or check the configuration of a known working machine.
-
- If you're only using loopback, you don't have a broadcast address.
-
- * Your gateway address. This is the address of the machine which
- is your "gateway" to the outside world (i.e. machines not on your
- subnet). In general the gateway machine has an IP address identical
- to yours but with a ".1" in the last position; e.g. if your IP
- address is 128.253.154.32, your gateway might be 128.253.154.1.
- Your network admins will provide you with the IP address of your
- gateway.
-
- If you're only using loopback, you don't have a gateway address.
- If your network is not connected to the Internet, that is, it
- is a standalone network, then you don't have a gateway, and
- therefore don't need a gateway address.
-
- * Your nameserver address. Most machines on the net have a name
- server which translates hostnames into IP addresses for them.
- Your network admins will tell you the address of your name server.
- You can in fact run a nameserver on your own machine by running
- named, in which case the nameserver address is 127.0.0.1. However,
- But it is not required that you run named at all; see section
- 4.2.2.1.
-
- If you're only using loopback, you don't have a nameserver
- address. (After all, you're only connecting to yourself.)
-
- SLIP USERS: You may or may not require any of the above information
- except for a nameserver address. Depending on how your slip access
- is achieved, you will either be given an ip address to use, in
- which case you probably already know it, or the slip server will
- dynamically allocate one for you. How to handle this situation is
- described in section 5.
-
- NET-2 supports full routing, multiple routes, subnetworking (at
- this stage on byte boundaries only), the whole nine yards. The above
- describes most basic TCP/IP configurations. Yours may be quite
- different: when in doubt, consult your local network gurus and check
- out the man pages for "route" and "ifconfig" included with the net-032
- package. Configuring TCP/IP networks is very much beyond the scope of
- this document; the above should be enough to get most people started.
-
- 4.2 /etc/rc.d/rc.inet1 and /etc/rc.d/rc.inet2
-
- For the non-UNIX wizard: "rc" files are run at bootup time by the
- "init" program and start up all of the basic system programs, such
- as sendmail, cron, etc. as well as the NET-2 daemons (such as inetd).
- They are analogous to the MS-DOS autoexec.bat file, and "rc" might
- stand for "runtime commands". For NET-2 the rc files are found in
- /etc/rc.d. It doesn't really matter where you keep them, as long as
- init can find them. (We'll go into this later).
-
- First things first. The file /etc/rc.d/rc.inet1 configures the basic
- TCP/IP interface to your machine, using two programs: /etc/ifconfig
- and /etc/route.
-
- /etc/ifconfig is used for configuring interface with the parameters
- that they require to function, such as IP addresses, network masks,
- broadcast addresses and the like.
-
- /etc/route is used to create entries in a table (the routing table)
- that the networking code will look in, to determine where to send
- datagrams that it wishes to transmit.
-
- Note that in the previous NET-1 code, the name of the interface
- configuration program was "config". However, the "standard" for UNIX
- system TCP/IP configuration is to use ifconfig and route, and this has
- been implemented with NET-2.
-
- THEREFORE: Be sure NOT to use /etc/config in your rc files. "config"
- will not work with NET-2, and if you try and use it you will see
- messages mentioning "old-style ioctl", and it wont work. You should
- only run rc.inet1 and rc.inet2 at boot time (or rc.net after you have
- converted it).
-
- NOTE: The standard SLS "rc" file file calls "/etc/rc.net" instead
- of "/etc/rc.d/rc.inet1" and "/etc/rc.d/rc.inet2". The SLS rc.net
- file can be treated as just the rc.inet1 and rc.inet2 files in
- one file. So when you see rc.inet1, and rc.inet2 below, just add the
- same commands into /etc/rc.net, and you will achieve the same result.
- It is important that the commands in rc.inet1 be run first, so make
- sure those commands are at the top of the file.
-
- Below you're going to edit rc.inet1 to use the correct ifconfig and
- route commands for your machine. But first, you need to know the
- information about your network setup in section 4.1, above.
-
- 4.2.1 Editing rc.inet1
-
- Edit the file /etc/rc.d/rc.inet1. This file uses the "ifconfig" and
- "route" commands to configure your network interface at boot time.
- SLS Users: Remember that SLS uses just rc.net, and these command
- should be called first, so put them at the top of the file.
-
- You may need to do some heavy surgery on this file to get it to look
- right; it may be easier to delete it and start from scratch. Given
- the information above, a possible rc.inet1 for a machine that has
- a single ethernet interface should look like:
-
-
- #!/bin/sh
- # Portion of /etc/rc.d/rc.inet1 to configure the loopback interface
-
- HOSTNAME=`hostname`
-
- # Attach the loopback device.
- /etc/ifconfig lo 127.0.0.1 # uses default netmask 255.0.0.0
- /etc/route add 127.0.0.1 # a route to point to the loopback device
- # End Loopback Definition
-
- # Portion of /etc/rc.d/rc.inet1 to configure an ethernet interface
-
- # IF YOU HAVE AN ETHERNET CONNECTION, use these lines below to configure the
- # eth0 interface. If you're only using loopback or SLIP, don't include the
- # rest of the lines in this file.
-
- # Edit for your setup.
- IPADDR="128.253.154.32" # REPLACE with YOUR IP address!
- NETMASK="255.255.255.0" # REPLACE with YOUR netmask!
- NETWORK="128.253.154.0" # REPLACE with YOUR network address!
- # Note: NETWORK MUST be in
- # /etc/networks
- BROADCAST="128.253.154.255" # REPLACE with YOUR broadcast address, if you
- # have one. If not, leave blank and edit below.
- GATEWAY="128.253.154.1" # REPLACE with YOUR gateway address!
-
- /etc/ifconfig eth0 ${IPADDR} netmask ${NETMASK} broadcast ${BROADCAST}
- # If you don't have a broadcast address, change the above line to just:
- # /etc/ifconfig eth0 ${IPADDR} netmask ${NETMASK}
-
- /etc/route add ${NETWORK} # MUST HAVE AN ENTRY IN
- # /etc/networks !!!
-
- /etc/route add default gw ${GATEWAY} metric 1 # Only necessary if your
- # network has an Internet
- # connection.
- # End of Ethernet Configuration
-
-
- This is a basic rc.inet1 to run the ifconfig and route commands
- needed to set up a basic TCP/IP connection. Edit this for your setup.
- If you do not have an ethernet interface, and either have a standalone
- workstation (no network connection at all), or you use SLIP, then
- you need only the two lines that refer to the loopback interface "lo"
- as noted.
-
- To ensure that this will be run at boot time, make sure that you
- include the command:
-
- /bin/sh /etc/rc.d/rc.inet1
-
- in your /etc/rc, or in your /etc/inittab (if you're running the
- sysvinit package). In general, make sure that rc.inet1 is run
- BEFORE rc.inet2 at boot time. You may wish to run rc.inet1 and
- rc.inet2 from /etc/rc or /etc/rc.local. Or you can run them from
- /etc/inittab. Either way is fine, but don't run one without the other.
-
-
- 4.2.2 Editing rc.inet2
-
- Having run rc.inet1, you now your interfaces configured with addresses,
- and a routing table with enough information to get you started. You'll
- now want to do something with them.
-
- The rc.inet2 script is also run at boot time, AFTER rc.inet1.
- It starts up various TCP/IP daemons such as inetd, portmapper,
- and so on. Remember that SLS uses just rc.net, thus, the following
- should appear at the bottom of the file.
-
- Now would be a really good time for you to read Olafs Network
- Administrators Guide. It will help you decide what you need to
- put in this file, and what you don't need to put in this file.
-
- But Briefly:
- 'inetd' is a program that sits in the background and manages
- internet connection requests and the like. It is smart enough
- that you don't need to leave a while bunch of servers running
- even when there is nothing connected to them. When it sees an
- incoming request for a particular service, eg telnet or ftp, it
- will check the /etc/services file, and find what server program
- needs to be run to manage the request, will start it, and hand
- the connection over to it. Imagine it as a master server for you
- internet servers.
-
- 'syslogd' is a daemon (server that runs in the background) that
- handles all system logging. It accepts messages generated for it,
- will distribute them according to the specifications in
- /etc/syslogd.conf. For example, certain types of messages you will
- want to send to the console and also to log to a file, while others
- will need only be logged, while others yet again, will only need
- to go to the console. syslogd allows you to specify what messages
- you want to send where.
-
- For a more complete and detailed description of how all the networking
- bits and pieces fit together, please get Olaf Networking Guide as
- described in section 0.3 (Related Documentation).
-
-
- You will probably want to comment out most of this file, especially
- if you're not planning on using NFS (Network File System). You
- MUST leave the stanza to run inetd and syslogd uncommented. Note
- that if you DON'T uncomment everything but inetd and syslogd,
- you may run into network problems at first. The best bet is to
- comment all of these things out, get yourself on the network, and
- then worry about configuring the rest of the clients in rc.inet2.
-
- If you're not going to be using NFS, you can comment out the lines
- to run: ugidd, mountd, nfsd, pcnfsd, and bwnfsd.
-
- You can comment out the stanza to run "umail" unless you have that
- package. In general, most of the things found in rc.inet2 are "sold
- separately". I recommend starting only inetd and syslog at first
- until you get everything going.
-
- The following is a copy taken from Fred's net-032 distribution.
- Please check the "NET" declaration, as some distributions might
- keep the network daemons in another directory.
-
- Each of the stanzas basically says: "If the filename xxxxxx exists,
- and it is an ordinary file (not a directory, pipe, etc.) then
- execute the following commands".
-
-
- #! /bin/sh
- #
- # rc.inet2 This shell script boots up the entire INET system.
- # Note, that when this script is used to also fire
- # up any important remote NFS disks (like the /usr
- # distribution), care must be taken to actually
- # have all the needed binaries online _now_ ...
- #
- # Version: @(#)/etc/rc.d/rc.inet2 2.18 05/27/93
- #
- # Author: Fred N. van Kempen, <waltje@uwalt.nl.mugnet.org>
- #
-
- # Constants.
- NET="/usr/etc"
- IN_SERV="lpd"
- LPSPOOL="/var/spool/lpd"
-
- # At this point, we are ready to talk to The World...
- echo -e "\nMounting remote file systems ..."
- /bin/mount -t nfs -v # This may be our /usr runtime!!!
-
- echo -e "\nStarting Network daemons ..."
- # Start the SYSLOG daemon. This has to be the first server.
- # This is a MUST HAVE, so leave it in.
- echo -n "INET: "
- if [ -f ${NET}/syslogd ]
- then
- echo -n "syslogd "
- ${NET}/syslogd
- fi
-
- # Start the SUN RPC Portmapper.
- if [ -f ${NET}/rpc.portmap ]
- then
- echo -n "portmap "
- ${NET}/rpc.portmap
- fi
-
- # Start the INET SuperServer
- # This is a MUST HAVE, so leave it in.
- if [ -f ${NET}/inetd ]
- then
- echo -n "inetd "
- ${NET}/inetd
- else
- echo "no INETD found. INET cancelled!"
- exit 1
- fi
-
- # Start the NAMED/BIND name server.
- if [ ! -f ${NET}/named ]
- then
- echo -n "named "
- ${NET}/named
- fi
-
- # Start the ROUTEd server.
- if [ -f ${NET}/routed ]
- then
- echo -n "routed "
- ${NET}/routed -q #-g -s
- fi
-
- # Start the RWHO server.
- if [ -f ${NET}/rwhod ]
- then
- echo -n "rwhod "
- ${NET}/rwhod -t -s
- fi
-
- # Start the U-MAIL SMTP server.
- if [ -f XXX/usr/lib/umail/umail ]
- then
- echo -n "umail "
- /usr/lib/umail/umail -d7 -bd </dev/null >/dev/null 2>&1 &
- fi
-
- # Start the various INET servers.
- for server in ${IN_SERV}
- do
- if [ -f ${NET}/${server} ]
- then
- echo -n "${server} "
- ${NET}/${server}
- fi
- done
-
- # Start the various SUN RPC servers.
- if [ -f ${NET}/rpc.portmap ]
- then
- if [ -f ${NET}/rpc.ugidd ]
- then
- echo -n "ugidd "
- ${NET}/rpc.ugidd -d
- fi
- if [ -f ${NET}/rpc.mountd ]
- then
- echo -n "mountd "
- ${NET}/rpc.mountd
- fi
- if [ -f ${NET}/rpc.nfsd ]
- then
- echo -n "nfsd "
- ${NET}/rpc.nfsd
- fi
-
- # Fire up the PC-NFS daemon(s).
- if [ -f ${NET}/rpc.pcnfsd ]
- then
- echo -n "pcnfsd "
- ${NET}/rpc.pcnfsd ${LPSPOOL}
- fi
- if [ -f ${NET}/rpc.bwnfsd ]
- then
- echo -n "bwnfsd "
- ${NET}/rpc.bwnfsd ${LPSPOOL}
- fi
-
- fi
- echo network daemons started.
- # Done!
-
- 4.2.2.1 "To named or not to named... that is the question."
-
- "I dub thee ... "
- Named is the nameserver daemon that runs under TCP/IP. It allows
- your machine to serve the name lookup requests of other machines...
- that is, if a machine wants to find the IP address for
- "goober.norelco.com", and you have this machine's IP address in your
- named database, then you can service the request and tell other
- machines what goober's address is.
-
- Under older implementations of Linux TCP/IP, to create aliases for
- machine names (even for your own machine), you were required to run
- named on your Linux box to store name->IP address translations. The
- problem with this is that named is generally difficult to setup and
- maintain. To solve this problem, a program called "hostcvt.build"
- was made available on Linux systems to translate your /etc/hosts file
- (see section 4.3) into named database files. However, even with
- this problem out of the way, running named on your system will cause
- some amount of CPU load and network traffic.
-
- The bottom line is this: You DO NOT need to run named on your
- Linux system. The SLS instructions will probably tell you to run
- hostcvt.build to set up named. This is simply unnecessary, UNLESS
- you want to make your Linux system a nameserver for some reason.
- Now, instead of putting hostnames into the named database, you can
- simply include them in the file /etc/hosts (section 4.3). When
- looking up names, your Linux system will first look in /etc/hosts
- and then ask the nameserver out on the net (if you have one).
-
- The only reason you may want to run named would be if:
- a) You're setting up a network of machines, and need a nameserver
- for one of them (and don't have a nameserver out on the net
- elsewhere);
- b) Your network admins want you to run your Linux system as a
- nameserver for some reason; or,
- c) You have a slow SLIP connection, and want to run a small
- cache-only nameserver on your Linux machine so that you don't
- have to go out on the phone line every time a name lookup
- occurs. (If you are only going to lookup a small number of
- machine names, and you know what they are, you can put their
- addresses in /etc/hosts instead.) Generally name lookup isn't
- that slow, and should work fine over most SLIP connections.
- d) You want to run a nameserver for fun and excitement.
-
- In general, you DO NOT need to run named: this means that you
- can comment it out from rc.inet2, and you don't have to run
- hostcvt.build. If you want to alias machines, for example you want
- to refer to "loomer.vpizza.com" just as "loomer", you can add an
- alias in /etc/hosts instead. There is no reason to run named unless
- you truly want a full nameserver on your machine. If you already
- have a nameserver (most machines on the Internet do, and your net
- admins will tell you its address), don't bother running named.
-
- If you're only using loopback, you can run named and set your
- nameserver address to 127.0.0.1, but that's pointless. (No pun
- intended.) You don't need a nameserver at all if you use only
- loopback; the only hostname you know is your own, and it's in
- /etc/hosts (see section 4.3, below).
-
- Have I mentioned Olafs Network Administration Guide as described
- in section 0.3 (Related Documentation) yet ??
-
- 4.3 /etc/hosts
-
- /etc/hosts contains a list of IP addresses and the hostnames they
- map to. In this way, you can refer to other machines on the network
- by name, as well as by IP address. Using a nameserver (see section 4.1)
- also allows you to do the name->IP address translation automatically.
- (Running named allows you to run your own nameserver on your Linux
- box. See section 4.2.2.1 above.)
-
- This file needs to contain at least an entry for 127.0.0.1 with
- the name "localhost". If you're not only using loopback, you need
- to contain an antry for your IP address, with your full hostname
- (such as loomer.vpizza.com). You may also wish to include entries
- for your gateway and network addresses.
-
- For example, if "loomer.vpizza.com" has the IP address
- "128.253.154.32", my /etc/hosts file would look like:
-
- # /etc/hosts: List of hostnames and IP addresses
- 127.0.0.1 localhost
- 128.253.154.32 loomer.vpizza.com loomer
- # end of hosts
-
- Once again, edit this for your own needs. If you're only using
- loopback, the only line in /etc/hosts should be for 127.0.0.1, with
- both "localhost" and your hostname after it.
-
- Note that in the second line, above, there are two names for
- 128.253.154.32: "loomer.vpizza.com" and just "loomer". The first name
- is the full hostname of the machine. The second is an alias---it
- allows me to just use "rlogin loomer" without having to type in the
- entire name.
-
- 4.3.1 Important note regarding /etc/hosts from NET-032.
-
- If you using the hosts file that came with NET-032, then:
- The line "%%IP%% %%HOST%% %%ALIAS%%" needs to be deleted from
- this file! This is a "tag" line used by Fred's experimental net
- config scripts. Matt Welsh is now writing a new set of scripts which
- don't use these lines. In any of these files, you see curious lines
- with entries such as "%%NAME%%", these lines MUST be deleted. If you
- don't delete them, you may have lots of strange errors and overflowing
- syslog files.
-
- 4.4 /etc/networks
-
- The /etc/networks file lists the names and addresses of your own,
- and other, networks. It is used by the route command, and allows
- you to specify a network by name, should you so desire.
-
- NOTE: Every network you wish to add a route to using the 'route'
- command MUST have an entry in /etc/networks
-
- Its format is similar to that of the /etc/hosts file, (Sec 4.3)
- and an example one might look like:
-
- #
- # /etc/networks: list all networks that you wish to add route commands
- # for in here
- #
- default 0.0.0.0 # default route - mandatory
- loopnet 127.0.0.0 # loopback network - mandatory
- mynet 128.253.154.0 # Example network CHANGE to YOURS
- #
- # end of networks
-
-
- 4.5 /etc/host.conf
-
- The system has some library functions called the resolver library.
- This file specifies how your system will lookup host names. It should
- contain the two lines:
-
- order hosts,bind
- multi on
-
- These two lines tell the resolve libraries to first check the
- /etc/hosts file for any names to lookup, and then ask the nameserver
- (if one is present). The "multi" entry allows you to have multiple
- IP addresses for a given machine name in /etc/hosts.
-
- This file comes from the implementation of the resolv+ bind
- library for Linux. You can find further documentation in the
- resolv+(8) man page (if you have the man page available).
-
- If you don't, they are available from:
- Site: src.doc.ic.ac.uk [146.169.2.1]
- Directory: /computing/comms/tcpip/nameserver/resolv+
- File: resolv+2.1.1.tar.Z
-
- This file contains resolv+.8, which is the man page for the
- resolver library.
-
- 4.6 /etc/resolv.conf
-
- This file actually configures the system name resolver.
- This file contains two types of entries: The addresses of your
- nameservers (if any), and the name of your domain (if you have one).
- If you're running your own nameserver (i.e., you're running named
- on your Linux machine: see section 4.2.2.1), then the address of
- your nameserver is just 127.0.0.1 (the loopback address).
-
- Your domain name is your fully-qualified hostname (if you're a
- registered machine on the Internet, for example), with the hostname
- chopped off. That is, if your full hostname is loomer.vpizza.com,
- your domain name is just "vpizza.com", without the hostname ("loomer").
-
- For example, if your machine is goober.norelco.com, and has a
- nameserver at the address 128.253.154.5, your /etc/resolv.conf would
- look like:
-
- domain norelco.com
- nameserver 127.253.154.5
-
- You can specify more than one nameserver. Each one
- must have a "nameserver" line of its own in resolv.conf.
-
- If you're only using loopback, you don't need a nameserver.
-
- 4.7 /etc/HOSTNAME
-
- This is a new file; it contains the full hostname of your machine
- (with the domain name). It is used by the 'hostname' command, to
- saveyou having to supply the hostname as an argument. For example,
- the machine above would have the file /etc/HOSTNAME:
-
- goober.norelco.com
-
- That's all.
-
- 4.8 /etc/rc.local
-
- Change the line in /etc/rc.local (or /etc/rc, depending on your
- setup) which sets your system's hostname, to
-
- /bin/hostname -S
-
- (You have a new hostname in /bin.) This sets your hostname from
- the name found in /etc/HOSTNAME. If you don't like this (personally
- I don't), just do:
- /bin/hostname -S <your-hostname>
-
- For example,
- /bin/hostname -S loomer.vpizza.com
-
- It IS important that you give a full hostname (with domain name)
- in /etc/HOSTNAME. This allows the hostname command to set the
- host AND domainname in one shot.
-
- IMPORTANT: The hostname found in /etc/HOSTNAME *must* be a valid
- hostname. This means that it must be found in /etc/hosts (or that
- your nameserver must be able to resolve it, but you should put it
- in /etc/hosts in case your nameserver is down).
-
- 4.9 Other files.
-
- There are of course many other files in /etc which you may need to
- dabble with later on. Instead of going into them here, I'm going to
- provide the bare minimum to get you on the net. More information will
- be provided in later versions of the NET-2 HOWTO.
-
- Once you have all of the files set up, and everything in the
- right place, you should be able to reboot your new kernel and
- net away to your heart's content. However, I strongly suggest
- that you keep a bootable copy of your old kernel and even possibly
- a "recovery disk" (say, the SLS a1 disk, or HJLu's single disk
- boot disk) in case you hosed your /etc/rc files, for example,
- and can't login when you boot.
-
-
- 5. Configuring SLIP.
-
- SLIP (Serial Line Internet Protocol) allows you to use TCP/IP
- over a serial line, be that a phone line, with a dialup modem, or
- a leased asynchronous line of some sort. Of course, to use SLIP you'll
- need access to a dial-in SLIP server in your area. Many universities
- and businesses provide SLIP access all over the world.
-
- SLIP uses the serial ports on your machine to carry IP datagrams.
- To do this is must take control of the serial device. Slip devices
- are named 'sl0', 'sl1' etc, how do these correspond to your serial
- devices ? The networking code uses what is called an IOCTL (I/O
- control) call to change the serial devices into slip devices. There
- are two programs supplied that can do this, they are 'dip' and
- 'slattach'.
-
- 'dip' (Dialup IP) is a smart program that is able to set the speed
- of the serial device, command your modem to dial the remote end of
- the link, automatically log you into the remote machine, search for
- messages sent to you and extract information from them such as your
- IP address, and perform the IOCTL to change the serial device over
- to a slip device.
-
- 'slattach' on the other hand does very little other than set the
- serial device speed and perform the IOCTL to convert it to a slip
- device.
-
- When do you use which ? You would use dip when your link to the
- machine that is your slip server is a dialup modem, or some other
- temporary link. You would use 'slattach' when you have a leased
- line, perhaps a cable, between two machines, and there is no special
- action needed to get the link working. See section 5.4 for more
- information.
-
- Configuring SLIP is much like configuring an Ethernet interface
- (please read section 4.0 above). However, there are a few key
- differences.
-
- First of all, slip links are unlike an Ethernet network in that
- there are only ever two hosts on the network, one at each end.
- Unlike an ethernet that is available for use as soon as you are
- cabled, with slip, depending on the type of link you have, you
- may have to command your modem to establish the connection to
- the remote modem. Dialing in and connecting to your SLIP server is
- usually done at boot time, usually by a program called "dip"
- (found in the "dip" subdir of the net-032 package). "Dip" not only
- dials and logs you into the SLIP server, but it also initiates the
- SLIP connection and runs the appropriate ifconfig and route commands
- to initialize the device. Therefore, the only lines needed in
- /etc/rc.d/rc.inet1 are the few commands to initilize the loopback
- connection at the top (see section 4.2.1 above).
-
- If you're not using DIP, you may indeed have to edit rc.inet1 for
- your SLIP parameters.
-
- Also, there are two types of SLIP servers: Dynamic IP address
- servers and static IP address servers. Dynamic servers allocate
- a new, different IP address to you every time you dialin and
- initiate a connection. Static servers give you the same address
- every time. Almost every SLIP server will also prompt you for
- a username and password when dialing in: DIP can handle logging
- you in automatically.
-
- Essentially, configuring a SLIP connection is just like configuring
- for loopback or ethernet. The main differences are discussed below.
- Read section 4.0 above for information on configuring your TCP/IP
- files, and apply the changes below.
-
- 5.1 Static SLIP server connections using a dialup line.
-
- If you have a static-allocation server (same IP address every time),
- then you may want to put entries for your hostname and IP address
- (since you know what your IP address is!) in /etc/hosts. You should
- also configure the other files listed in section 4.0: rc.inet2,
- host.conf, resolv.conf, /etc/HOSTNAME, and rc.local). Remember that
- when configuring rc.inet1, you don't need to run the ifconfig and
- route commands other than the two for the loopback interface (if
- you're using DIP to dial your connection).
-
- In general, your gateway is the IP address of your SLIP server.
- Because DIP handles the configuration of the route, you probably
- don't need to know this, but in some cases you might have to run the
- appropriate ifconfig or route commands in /etc/rc.d/rc.inet1 to
- get it to work correctly. Instead of using "eth0" as your interface
- name, SLIP connections use "sl0". Keep in mind that you can't
- ifconfig sl0 until you have dialed the connection and connected to
- the SLIP server.
-
- Also, you may need to use the "pointopoint" argument to ifconfig if
- DIP does not do it correctly. For example, if your SLIP server's
- address is 44.136.8.5, and your IP address is 128.253.154.32, you may
- need to run the command
-
- # /etc/ifconfig sl0 128.253.154.32 pointopoint 44.136.8.5
-
- See the man pages for ifconfig in the net-032 package.
-
- 5.2 Static SLIP server connections using a leased line or cable.
-
- If you have a leased line, or cable to your slip server, then you
- do not need to worry with the hassle of causing your modem to
- dial and establish the connection. In this situation the 'slattach'
- program is the best solution for configuring your SLIP link.
-
- I can think of no better way of describing the process than by
- illustration. In your rc.inet1 file you would have something similar
- to the following:
-
- # Portion of /etc/rc.d/rc.inet1 for leased line static slip connection
- #!/bin/sh
- IPADDR="128.253.154.32" # REPLACE with YOUR IP address!
- REMADDR="128.253.154.33" # REPLACE with YOUR OTHER SLIP servers address!
-
- slattach -p cslip -s 19200 /dev/ttyS0
- /etc/ifconfig sl0 $IPADDR pointopoint $REMADDR up
- /etc/route add default gw $REMADDR
-
- # End
-
- slattach allocates the first unallocated slip device to the serial
- device specified. slattach starts with 'sl0'. Therefore the first
- slattach command attaches slip device 'sl0' to the serial device
- specified, 'sl1' the next time etc.
-
- Note also that the first parameter that slattach accepts is one to
- specify the protocol. At present the only working values are
- 'slip', and 'cslip'. 'cslip' is compressed slip, it is the same
- slip, except that the datagrams headers have been compressed to
- reduce overhead on the link. On good clean links this is recommended.
- In future protocols such as PPP, and KISS (for Amateur Radio use)
- will be offered.
-
- After you have 'slattached' the interface, you can now configure
- it with ifconfig as you would an ethernet interface, but since
- there is only one other machine that you can talk to directly via
- the link you do not need to worry about netmasks and the like.
- Normally you would point your default route to the slip interface,
- as it is your connection to every other machine. The pointopoint
- parameter should automatically add a route to the machine at the
- other end of the link. Its primary function is to tell your machine
- that there are no other hosts on that network interface.
-
- If you have more than one slip interface then you will have routing
- considerations to make. You will have to decide what routes to
- add, and those decisions can only be made on the basis of the
- actual layout of your network connections.
-
- 5.3 Dynamic SLIP server connections using a dialup line.
-
- If your SLIP server allocates a new IP address to you every time
- you dialin, you don't know your IP address at all, so you can't
- include an entry in /etc/hosts for your machine. (If you want, you
- can place your hostname in /etc/hosts with the address 127.0.0.1).
-
- Most dynamic SLIP servers tell you your IP address when you initiate
- the connection. For example, it may print a string such as, "Your IP
- address is 128.253.154.10. Server address is 128.253.154.1." DIP will
- need to know these numbers when it configures the connection. See
- section 5.3 below on using DIP.
-
- If you use DIP, it does all of the work of configuring the
- connection when you dialin, so rc.inet1 only needs the two lines
- to configure the loopback address (see section 4.2.1 above).
- Also, see section 5.1 above. You need to configure all of
- the files listed in section 4.0. Your gateway address (should you
- need to know it) will be the address of the SLIP server. Also,
- you may need to run ifconfig on sl0 using the SLIP server's address
- as the "pointopoint" argument (see section 5.1 above). However, if
- you use DIP, it should be able to do all of the ifconfig and route
- commands for you.
-
- One good way to figure out how to configure SLIP on your machine is
- to find someone else who uses the SLIP server (it can be on a PC,
- Mac, UNIX box, whatever) and find out what numbers they use.
-
-
- 5.4 Using DIP.
-
- DIP can simplify the process of dialing into the SLIP server, logging
- in, starting the connection, and configuring the sl0 device with
- the appropriate ifconfig and route commands.
-
- Essentially, to use DIP you'll write a "chat script" which is
- basically a list of commands to send to DIP along with commands for
- logging in, starting the connection, and so on. See "sample.dip"
- in the net-032 package for an explanation. DIP is quite a powerful
- program, with many options. Instead of going into all of them here
- you should look at the READMEs and the sample files from tsx-11 and
- the net-032 distribution.
-
- You may notice that the sample.dip script assumes that you're using
- a static SLIP server, so you know what your IP address is beforehand.
- For dynamic SLIP servers, the newer version of dip include a command
- you can use to automatically read and configure your interface
- with the address printed by your server. The following sample was
- contributed by Paul Mossip, and is probably a good starting point
- for you:
-
-
- #
- # Connection script for SLIP to knoware.nl.mugnet.org
- #
-
- # Fetch the IP address of our target host.
- main:
-
- # Set the desired serial port and speed.
- port /dev/cua0
- speed 38400
-
- # Reset the modem and terminal line.
- reset
-
- # Prepare for dialing.
- send ATZ1\r
- wait OK 4
- if $errlvl != 0 goto error
- dial 666-0999 ## Change to your servers number!
- if $errlvl != 0 goto error
- wait CONNECT 60
- if $errlvl != 0 goto error
-
- # We are connected. Login to the system.
- login:
- sleep 3
- send \r\n\r\n
- wait gracelands> 20 ## Change to your servers prompt
- if $errlvl != 0 goto error
- send login\n
- wait name: 10 ## Wait username: prompt
- if $errlvl != 0 goto erro
- send elvisp\n ## Change to your own!
- wait ord: 10 ## Wait password prompt
- if $errlvl != 0 goto error
- send alive\n ## Change to your own!
- wait gracelands> 10
- if $errlvl != 0 goto error
- send slip\n ## Change to suit your server
- wait SLIP 30 ### Wait for SLIP prompt
- if $errlvl != 0 goto error
- get $local remote 10 ## Assumes the server sends your IP..
- if $errlvl != 0 goto error ## address as soon as you enter slip.
- get $remote gracelands ## slip server address from /etc/hosts
- done:
- print CONNECTED to $remote with address $rmtip we are $local
- default
- mode SLIP
- goto exit
- error:
- print SLIP to $host failed.
- exit:
- #
- # End dip script
-
-
- The example above will automatically point your default route via your
- slip link, if this is not what you want, you might have an ethernet
- connection that should be your default route, then remove the 'default'
- command.
-
- The above example is fairly robust. Please refer to the 'dip' man
- page for more information.
-
- It should be simple to modify the code for DIP in the file attach.c
- to run the route and ifconfig commands that work for you automatically.
-
- 5.5 Configuring your Linux Machine as a SLIP Server.
-
- Note: Some of the information below came from the dip man pages,
- where in fact how to run Linux as a slip server is briefly documented.
-
- To configure Linux as a slip server, you need to create Special
- slip accounts for users, where dip (in slave mode) is used as the
- login shell. Fred suggests that he has a convention of having all
- of his Slip accounts begin with a capital 'S', eg "Sfredm".
-
- Because the login program won't accept arguments to the login shell,
- you will need to create a small program that looks like the following:
-
- /* dip-i.c - from a mail message of Karl kkeyte@esoc.bitnet */
- int main()
- {
- execlp("dip", "dip", "-i", (char *) 0);
- }
-
- Compile it with: 'gcc -O dip-i.c -o dip-i'
-
- Give it permissions 555. I recommend calling it /usr/bin/dip-i as
- shown below.
-
- A sample /etc/passwd entry for a Slip user looks like:
-
- Sfredm:ij/SMxiTlGVCo:1004:10:UUNET:/tmp:/usr/bin/dip-i
- ^^ ^^ ^^ ^^ ^^ ^^ ^^
- | | | | | | \__ shell program running
- | | | | | | dip -i as login shell
- | | | | | \_______ Home directory
- | | | | \_____________ User Full Name
- | | | \__________________ User Group ID
- | | \______________________ User ID
- | \________________________________ Encrypted User Password
- \___________________________________________ Slip User Login Name
-
-
- After the user logs in, the login(1) program, if it finds and
- verifies the user ok, will execute the shell program 'dip-i' which
- will execute dip command in input mode (-i). Dip now scans the
- /etc/net/diphosts file for an entry for the given user name.
- Therefore, each slip user must also have an entry in
- /etc/net/diphosts.
-
-
- 5.6 /etc/net/diphosts
-
- /etc/net/diphosts is used by dip to lookup preset configurations for
- remote hosts. These remote hosts might be users dialing-into your
- linux machine, or they might be for machines that you dial into
- with your linux machine.
-
- The general format for /etc/net/diphosts is as follows:
-
- Suwalt::145.71.34.1:SLIP uwalt:CSLIP,1006
- ^ ^ ^ ^ ^ ^
- | | | | | \___ MTU
- | | | | \_________ protocol (SLIP, CSLIP,
- | | | | KISS, PPP)
- | | | \___________________ comment field ("gecos" :-)
- | | \________________________________ IP address of the other
- | | side, or host.domain.name
- | \___________________________________ unused (compat. with passwd)
- \________________________________________ login name (as returned by
- getpwuid(getuid()) )
-
-
- An example /etc/net/diphosts entry for a remote slip user might be:
-
- Sfredm::145.71.34.1:SLIP uwalt:SLIP,296
- which specifies a SLIP link with MTU==296, or
-
- Sfredm::145.71.34.1:SLIP uwalt:CSLIP,1006
- which specifies a CSLIP-capable link with MTU of 1006.
-
- When a user logs in, they will receive a normal login, and
- password prompt, at which they should enter their slip-login
- userid and password. If they check out ok, then the user will
- see no special messages, they should just change into slip mode
- at their end, and then they should be able to connect ok, and be
- configured with the paramters from the diphosts file.
-
- 5.7 Configuring PLIP interfaces.
-
- PLIP is like SLIP, in that it is used for providing point to point
- IP links between machines, except that it is designed to use the
- Parallel ports on your machine instead of the serial ports. Because
- it is possible to transfer more than one bit at a time with the
- Parallel port, it is possible to attain higher speeds with the
- plip interface than with the serial interface. In addition, even
- the simplest of parallel ports, printer ports, can be used, in
- lieu of you having to purchase conmparatively expensive 16550AFN
- UARTs for your serial ports.
-
- When compiling the kernel, there is only one file that might need
- to be looked at. That file is net/drv/plip/global.h, and it contains
- timers in mS. The defaults are probably going to be fine, unless you
- have an especially slow computer, in which case you might have to
- increase them on the machine at the other end of the link.
-
- A sample configuration for a plip interface might be:
-
- #!/bin/sh
- # Portion of /etc/rc.d/rc.inet1 for PLIP connection to local machine
-
- IPADDR='192.148.64.1' # Replace with YOUR IP Address
- REMADDR='212.194.167.1' # Replace with the address of YOUR OTHER HOST
-
- ifconfig pl0 $IPADDR pointopoint $REMADDR up # Configure PLIP interface
- route add default gw $REMADDR # Route to other machine.
-
- # End
-
- The pointopoint parameter has the same meaning as for SLIP, in
- that it specifies the address of the machine at the other end of
- the link.
-
- In almost all respects, you can treat a plip interface as though
- it were a slip interface, except that neither 'dip' nor 'slattach'
- can be, or are used.
-
- 5.7.1 PLIP Cabling Diagram.
-
- PLIP has been designed to use cables with the same pinout as those
- commonly used by the better known of the dos based pc-pc file transfer
- programs. The pinout diagram (taken from net/drv/plip/README) looks as
- follows:
-
- Pin Name Connect pin - pin:
- -------------- ----------------------
- GROUND 25 - 25
- D0->ERROR 2 - 15 15 - 2
- D1->SLCT 3 - 13 13 - 3
- D2->PAPOUT 4 - 12 12 - 4
- D3->ACK 5 - 10 10 - 5
- D4->BUSY 6 - 11 11 - 6
- D5 7*
- D6 8*
- D7 9*
- STROBE output 1*
- AUTOFD output 14*
- INIT output 16*
- SLCTIN output 17*
-
- Do not connect the pins marked with an asterisk (`*'). They are
- D5 (pin 7), D6 (pin 8) and D7 (pin 9). STROBE is pin 1, FEED is
- pin 14.
-
- Extra grounds are on pins 18, 19, 20, 21, 22, 23 and 24.
-
- If the cable you are using has a metallic shield it should be
- connected to the metallic DB-25 shell at one end only.
-
- 6. PPP (Under construction).
-
- There is now some ALPHA PPP software available. For the latest
- information relating to it, join the PPP channel on the niksula.hut.fi
- list server, and keep your eye on comp.os.linux.development.
- Already there have been some encouringly good reports for it.
-
- The PPP software comes in two parts. Some kernel modifications, and
- the ppp daemon. They are available at the following locations:
-
- ftp://ftp.gang.umass.edu/user/michael/linux-ppp-0.1.5.tgz
- ftp://ftp.gang.umass.edu/user/michael/pppd-0.1.4.tgz
-
- Please check that there isn't a later version there, and be
- sure to read any README files or the like that are there as
- well, as they will tell you how to install, where to report
- bugs and the like.
-
- 7. AX.25 (Under construction).
-
- Alan Cox has some experimental AX.25 code available for testing.
-
- 8. Are You Stuck ?
-
- Really ? Then you should read the man pages for ifconfig and route,
- included in the net-032 package, and understand their functions. These
- commands have a lot of flexibility, and because everyone's network
- setup is different, you may find a way to use ifconfig and route to
- get your connection working. If you do, feel free to send me some mail
- so I can include it in the next update of the NET-2 HOWTO. Because of
- my limited amount of experimental data, most of the discussion above
- is about my own setup, and I'd like to generalize it as much as
- possible.
-
- Matt is currently writing a set of scripts to simplify NET-2
- configuration. You can pick up the pre-alpha release from
- tc.cornell.edu, in the file /pub/mdw/netconf-0.3.tar.z. These scripts
- maintain a small database of network configuration info, and allow you
- to easily modify and configure your network interface. The scripts are
- far from complete: Matt has been waiting until the NET-2 interface
- itself stabilizes a bit more before upgrading it further.
-
- Another good place to look for help on setting up NET-2 is the
- O'Reilly and Associated book 'TCP/IP Network Administration',
- the one with the crab on the cover. Keep in mind that NET-2 is now
- a "standard" implementation of TCP/IP, this means that ifconfig
- and route work the same under Linux as they do on other UNIX systems.
- Keep also in mind that some of the arguments and options may differ
- slightly from those in the book.
-
- You might also search out the following documents which are an
- excellent source of tutorial information on tcp/ip:
-
- athos.rutgers.edu:/runet
- -rw-r--r-- 1 0 0 176218 Oct 20 1989 tcp-ip-admin.doc
- -rw-r--r-- 1 0 0 214199 Oct 20 1989 tcp-ip-admin.ps
- -rw-r--r-- 1 0 0 92106 Oct 20 1989 tcp-ip-intro.doc
- -rw-r--r-- 1 0 0 111478 Oct 20 1989 tcp-ip-intro.ps
-
- Also keep in mind that NET-2 _is_ developing very rapidly, it's
- one of the newest additions to the Linux kernel. Thus, all of the
- bugs haven't been worked out yet, so there may be some problems.
- However, a good rule of thumb is that if you were able to get TCP/IP
- working under kernels before 0.99.pl10, you should be able to get it
- working under NET-2 as well. There are still some issues dealing with
- performance to be fixed, but overall the system works. And, as with
- everything in Linux development, time will cure what ails NET-2.
- If it's absolutely unusable to you, go back to an earlier kernel
- version, and wait until things develop further. The code is still
- fairly new.
-
- 9. Common Problems and Solutions.
-
- Now that the NET-2 HOWTO has been out for a while, I've been
- able to gather some common problems (and answers!). Here are
- some things which I have learned from hearing from readers.
- If you run into a problem which should be included here,
- please send it along (even if you have the solution!).
-
- QUESTION: How do I know what version of NET software I am running?
-
- ANSWER: In the kernel messages when you boot your machine, you should
- see a line that describes your networking code. For example, mine
- looks like:
-
- Linux version 0.99.14l+NET-2EB4 (root@albert.vk2ktj.ampr.org.)
-
- This line, not terribly obviously, tells you that I am running
- NET-2E, Beta 4.
-
- QUESTION: When I try to use the network, or use SLIP, I get the
- error message "Network not reachable". What should I do?
-
-
- ANSWER: This message means that a machine somewhere in the path did
- not have a route to the destination network. Until you can demonstrate
- otherwise, it is the courteous thing to do, assume it is your
- machine. This is usually an indication that either your ifconfig or
- route commands are in some way wrong. You can look at the status of
- your ifconfig by using the command "ifconfig" by itself. This should
- tell you what NET-2 thinks your IP address, netmask, etc. are.
- You can use the command "route" by itself to get routing information.
- This will tell you what routes you have set up and what gateways
- (if any).
-
- The best way to test a SLIP or network connection is to use "ping"
- with IP addresses only. If you use hostnames, as in "ping loomer",
- if some part of name lookup isn't working you'll have trouble.
- To test just the network, NOT name lookup, use only IP addresses,
- as in "ping 128.253.154.32".
-
- For SLIP connections the best thing to do is to ping your
- SLIP server. If nothing comes back, then something is wrong with your
- slip port configuration, double check all of the steps detailed above.
- Try using "dip -v" which will print debugging information while DIP
- is dialing the server.
-
- If you get a response from your slip server, but not from anywhere else,
- then you are probably missing your default route, you may need to use
- the commands:
-
- # route del <your slip server address>
- # route add default gw <your slip server address>
-
- to get SLIP talking to the server. Once you can talk to the
- server, everything SHOULD work (if your server is set up correctly!).
-
- For Ethernet connections, try pinging your gateway. If you can talk
- to your gateway, you should be able to talk to the outside world.
- You may need more than one route (that is, more than one gateway).
- For example, some universities use one gateway for on-campus
- networks and another for off-campus networks.
-
- Either way, try pinging addresses on your local network, and remote
- addresses. If you can ping all addresses ok remote to your network,
- and some on your local network, but not others on your local network,
- then check your netmask setting.
-
- If the "network not reachable" message means that you can't
- talk to your gateway. This can be due to several things:
-
- a) Wrong route or ifconfig commands
- b) Ethernet card problems (see below)
- c) You didn't compile the kernel correctly (see below).
- d) There is in fact some sort of network failure elsewhere.
-
-
- QUESTION: I keep getting the error "eth0: transmit timed out".
- What does this mean?
-
- ANSWER: This usually means that your Ethernet cable is unplugged,
- or that the setup parameters for your card (I/O address, IRQ, etc.)
- are not set correctly. Check the messages at boot time and make
- sure that your card is recognized with the correct Ethernet address.
- If it is, check that there is no conflict with any other hardware
- in your machine, eg you might have a soundblaster sharing the same
- IRQ or i/o control port.
-
- QUESTION: I get errors "check Ethernet cable" when using the network.
-
- ANSWER: You probably have your Ethernet card configured incorrectly.
- For Etherlink cards, in the file /usr/src/linux/driver/net/CONFIG,
- change the line
- EL_OPTS = -UEL2_AUI
- to
- EL_OPTS = -DEL2_AUI
-
- This tells the card to use the AUI cable interface.
- Just make sure that all of the options for your card are set
- correctly in the CONFIG file, and rebuild your kernel.
-
-
- QUESTION: When I use NET-2, I get a "General protection" error
- or a panic from the kernel. How can I fix this?
-
- ANSWER: Remember that the NET-2 code is still on the buggy side,
- just because it's in mid-development. If you get a kernel panic
- while using NET-2, write down the EIP address (and the other
- information given in the panic message). The EIP is the address
- where the kernel paniced, usually of the form 0008:xxxxxxxx
- where "0008" is the segment descriptor for the kernel text, and
- "xxxxxxxx" is the offset into that segment (80386 programmers will
- know what this means).
-
- Use the command
- nm /usr/src/linux/tools/system | sort -n
- or
- nm /usr/src/linux/tools/zSystem | sort -n
-
- depending on whether or not you use a compressed kernel (zImage).
- This will print a listing of all symbols in the kernel text,
- simply scan down the list and look for the function that contains
- the EIP address in the kernel dump. There's the culprit.
-
- However, in some cases the EIP can be misleading; the kernel
- may panic at a place which is complete irrelevant to where the
- actual problem occurred. However, it is a good starting place;
- first, locate the function which contains the EIP address, and
- then check out the kernel code to see what might be wrong.
-
- Keep in mind that this will only work if you compile your own
- kernel and have the "system" file associated with it.
-
-
- QUESTION: How can I hang up the phone line when I'm done using
- SLIP?
-
- ANSWER: If you use dip to dial out on the SLIP line, just
- "kill -9" the dip process itself (dip won't die unless you kill
- it with SIGKILL or some other signal). When dip dies, the line
- should hang up. DIPs behaviour is being modified so that it will
- be more sociable and die when it is supposed to. If you are using
- the new dip, then 'dip -k' will kill any copy of dip that you
- have running, and hang up the line as well.
-
- If you don't use dip to dial out, either instruct your dialing
- program to hang up the line, or kill the dialing process.
-
-
- QUESTION: dip doesn't work. How do I make it work ?
-
- ANSWER: Check that the file permissions of dip are 6750, that is
- 'chmod 6750 dip'. Check also that dip is owned by root:
- 'chown root:dip dip'
-
-
- QUESTION: With SLIP, I get a connection open, but no data flows.
-
- ANSWER: This could be a number of things. First, check your routes
- and be sure that the gateway is set correctly. Attempt to ping
- your gateway; if you can't, then something is wrong with the routes.
-
- Another problem could be that your system and the SLIP server
- disagree about header compression. With 0.99.pl11 and above,
- SLIP automatically compresses packet headers. To turn off header
- compression, check the SL_COMPRESS option in the CONFIG file.
- In pl14 there will be supplied a 'setencap' command to allow you
- to configure compression.
-
-
- QUESTION: With SLIP, I get a connection, but after sending a small
- amount of data, the connection hangs.
-
- ANSWER: Probably an MTU problem. The MTU is the maximum packet
- size available for the network. For SLIP, your MTU is set in
- your dip dialing script with the "MTU" command. The default value
- is 1500, which means that the system can send packets of up to
- 1500 bytes in size. However, some SLIP servers (Berkeley SLIP,
- for example), use a smaller MTU (around 1006).
-
- Another thing to check if you are having erratic SLIP problems is
- flow control. You need to use hardware (RTS/CTS) flow control
- on your modem, and your modem and your computer must agree. XON/XOFF
- flow control is not practical for SLIP.
-
- 9.1 Not so common problems and solutions (Mostly NFS).
-
- QUESTION: How do I use my existing Novell fileserver with my
- Linux machine ?
-
- ANSWER: If you have the Novell NFS Daemon code then it is easy, just
- NFS mount the Novell volume that you wish to use. If you don't, and
- you are really desperate to be able to do this, and you have a spare
- pc machine laying about, you are in luck. Here is what you do:
-
- You configure the spare machine as a normal Novell workstation,
- mapping the appropriate Fileserver directories to virtual drives
- as you so desire. You then grab a copy of SOSS (Son Of Stans own
- Server) from your nearest ftp site, and run it on the same workstation.
- SOSS is an NFS server that will happily run on just about any pc.
- This will allow you to NFS export the Novell network drives. It has
- caveats in that it will not perform as well as directly mounting
- the Novell fileserver, that it requires another machine, and that it
- will generate roughly twice as much network traffic, but it will work.
-
- Stan's Own Server (NFS server).
-
- spdcc.com:pub/sos/soss.zoo
- spdcc.com:pub/sos/sossexe.zoo
-
- A version "couple of bugs fixed: IP numbers and subdirectories
- with extensions)" is available from:
- hilbert.wharton.upenn.edu:/pub/tcpip/soss.zip
-
- QUESTION: Files get corrupted when using NFS over wider area networks
- or SLIP, why ? How do I stop it ?
-
- ANSWER: Certain vendors (Sun primarily) shipped many machines running
- NFS without UDP checksums. Great on ethernet, suicide otherwise. UDP
- checksums can be enabled on most file servers. Linux has it enabled by
- default from pl13 onwards - but both ends need to have it enabled...
-
- QUESTION: Why are my NFS files all read only ?
-
- ANSWER: The Linux NFS server defaults to read only. RTFM the 'exports'
- and nfsd manual pages. With non Linux servers you may also need to
- alter /etc/exports
-
- QUESTION: I mount from a linux nfs server and while ls works I can't
- read or write files. How do I fix this ?
-
- ANSWER: You must mount a Linux filestore with rsize=1024,wsize=1024
- (or 2048 if you really want - 1024 is a better choice).
-
- QUESTION: I mount from a linux nfs server with a blocksize of between
- 3500-4000 and it crashes the Linux box regularly, why ?
-
- ANSWER: This is a known problem that is being worked on, refer to
- previous question. Don't you hate answers like that ? :)
-
- QUESTION: Can Linux do NFS over TCP ?
-
- ANSWER: No. To do this would require someone to spend the time to
- update the rpc code to add rpc stream record marking. It should work
- then.
-
- QUESTION: Why do I get loads of strange errors trying to mount a
- machine from a Linux box.
-
- ANSWER: This is possibly related to a restriction imposed by older
- NFS servers. Make sure your users are in 8 groups or less.
-
- QUESTION: Why are my Linux NFS clients very slow when writing to Sun
- & BSD systems ?
-
- ANSWER: NFS writes are normally synchronous, meaning that all file-
- -system changes occur in the order they transmitted, this means that
- if before NFS will allow you to write any more data, any previous
- write must have already completed, (you can disable this if you don't
- mind risking losing data). Worse still, BSD derived kernels, this
- includes Sun systems, tend to be unable to work in small blocks. Thus
- when you write 4K of data from a Linux box in the 1K packets it uses,
- BSD does this:
-
- read 4K page
- alter 1K
- write 4K back to physical disk
- read 4K page
- alter 1K
- write 4K page back to physical disk
- etc..
-
- Better systems don't have this problem. The Linux client is however
- quite slow anyway.
-
- QUESTION: I've heard NFS is not secure is this true ?
-
- ANSWER: Yes, totally. Running NFS in an uncontrolled environment is
- rather like leaving your front door open, painting 'On holiday' on
- your house and posting maps to every known criminal...
- In a fairly secure environment or when you can recover data from stupid
- misuse its pretty much OK. The worst someone can easily do is alter all
- the files on an NFS mounted disk, and/or crash the machine. So long as
- you don't mount your system files writable you should be mostly safe.
-
- QUESTION: I occasionally mount from lots of different places, do I have
- to mount them all each time I boot ?
-
- ANSWER: No you can use the automounter to mount disks as you access
- them.
-
- QUESTION: How do I stop things hanging when a server goes down ?
-
- ANSWER: There are three main NFS behaviours:
-
- soft: Your NFS client will report an error to the process
- concerned if an NFS server doesn't answer after a few
- retries. Most software handles this well - but not all.
-
- hard: Your NFS client will try forever unless killed off.
- Operations will be restarted when the NFS server
- recovers or reboots.
-
- hard,intr: As hard but ^C will also stop the NFS retrying. In
- a few cases, notably nfs mounted /usr/spool/mail disks,
- this doesn't help as the shell will be ignoring ^C when
- it checks you have mail.
-
- If you intend to leave your machine unattended, then choosing the
- 'soft' option is probably best, because while it might cause some
- problems to an application running, it won't halt your whole machine
- if a server that it is attached to goes down. If your machine will
- always have a human operator available, then the 'hard,intr' option
- might be best. The hard option would be best suited to you if you can
- afford to wait, and don't want the process writing to the server
- interrupted at all.
-
- QUESTION: Can I use two slip interfaces ?
-
- ANSWER: Yes. If you have, for example, three machines which you
- would like to interconnect, then you most certainly could use
- two slip interfaces on one machine and connect each of the other
- machines to it. Simply configure the second interface as you did
- the first. NOTE that the second interface will require a different
- IP address to the first. You may need to play with the routing a
- bit to get it to do what you want, but it should work.
-
- 10. Known bugs.
-
- There are several known bugs with the NET-2 software. Note that these
- may or may not be fixed with a newer version of the NET-2 code;
- therefore, I leave them here.
-
- The bugs here are for NET-2d, found in kernels 0.99.pl10, pl11,
- and pl12, and pl13, and pl14. NET-2e (currently in Beta), when
- released, may or may not have fixed these bugs.
-
- * Bug with route guessing code. If you ifconfig the "lo"
- interface before the "eth0" interface in rc.inet1, whenever you
- add a route, it will be added to "lo" instead of "eth0".
- (Simply use the "route" command by itself; it will display all
- of your routes. If your "default" route, which should be out
- on the ethernet, is for device "lo" instead of "eth0", then you're
- seeing this bug.)
-
- This is just a problem with the route guessing code. Several
- things can fix it: 1) ifconfig/route on "eth0" before "lo" in
- rc.inet1; or, 2) Set your netmask to 255.0.0.0 (which is reported
- to work, but I can't guarantee it). This should be fixed in NET-2e.
-
- * Missing IP packet fragmentation. Packet fragmentation allows the
- various protocol layers to "chop up" packets into smaller packets
- if the MTU (maximum tranfer unit) of one network differs from
- another. NET-2e should contain packet fragmentation/defragmentation
- code, but NET-2d currently does not.
- This now only applies to kernel earlier than pl14+, as it is now
- supported.
-
- * Weak NFS support. There have been a number of success stories with
- NFS under Linux, however, not all of the support is there. For
- one thing, the current NFS buffer size is much smaller, and
- therefore much slower, than other implementations of NFS.
-
- 11. Copyright Message. (We're not ogres, nor are we silly).
-
- The NET-2-HOWTO is copyright by Terry Dawson and Matt Welsh. A verbatim
- copy of this document may be reproduced and distributed in any medium,
- physical or electronic without permission of the authors. Translations
- are similarly permitted without express permission if such translations
- include a notice stating who performed the translation, and that it is
- a translation. Commercial redistribution is allowed and encouraged,
- however, the authors would like to be notified of any such
- distributions.
-
- Short quotes may be used without prior consent by the authors.
- Derivative works and partial distributions of the NET-2-HOWTO must
- include either a verbatim copy of this file, or make a verbatim copy
- of this file available. If the latter is the case, a pointer to the
- verbatim copy must be stated at a clearly visible place.
-
- In short, we wish to promote dissemination of this information through
- as many channels as possible. However, we wish to retain copyright on
- this HOWTO document, and would like to be notified of any plans to
- redistribute it. Further we desire that ALL information provided in
- this HOWTO be disseminated.
-
- If you have any questions relating to the conditions of this copyright,
- please contact Matt Welsh, the Linux HOWTO coordinator, at:
- mdw@sunsite.unc.edu, or +1 607 256 7372.
-
-
- 12. Miscellaneous.
-
- I'm sure that I've missed something. This NET-2 HOWTO was thrown
- together with the help of Matt Welsh, and Jeff Uphoff. Other major
- contributors have been Alan Cox, Fred van Kempen, and others just
- like yourself. Hopefully it will help you, and others out there, get
- networking under Linux.
-
- Future plans for the NET-2 HOWTO include a section on setting up
- your own Linux LAN (with SLIP and/or Ethernet), adventures in
- routing, and the use of netstat and other network administration
- under Linux. For now, the information here should be more than
- enough. :)
-
- If you have questions about setting up NET-2, feel free to mail me, or
- if you have any corrections, additions, or errata for this NET-2 HOWTO,
- send me any and all changes (cdiffs are nice, but I'm flexible).
-
- Of course, thanks to Fred, Linus, Ross, Phil, Paul, Don, Alan,
- Matt, and everyone else who helped to develop the NET-2 code and work
- on previous versions of TCP/IP for Linux and the NET-FAQ. Finally,
- Linux has a complete implementation of TCP/IP. It may not be for
- everyone yet. But for those who have an itch they want to scratch,
- happy hacking, here it is.
-
- Cheers,
-
- Terry Dawson, (terryd@extro.ucc.su.oz.au)
-
- 13. Change History.
-
- Changes from 1.8:
- correction to broadcast address calculation, thanks Andr'as Salamon
- tcp/ip tutorials added thanks to Gilbert Callaghan
- These annotations at the suggestion of Andy Burgess
- Shadow password section updated - thanks Rick Sladkey
- added Slip Server section - thanks Fred
- added /etc/net/diphosts section - thanks Fred
- enhanced the netmask description a little
- Revamped for 0.99.14
- Added Index
-
- Changes from 1.9:
- Added change history.
- Corrected Archive header now that I understand what it is there for
- Thanks to _everyone_ who helped me understand :)
- Ammended loopback route details - thanks Jeffrey A. Kintscher.
- First attempt at enlarging the configuration section to cope with
- different networks and different distributions thanks
- Eric Christensen.
- Reinstated /dev/arp as a required device. Oops.
- Finally added resolv+(8) man page reference.
- Tried to clean the slip section a bit.
- Added leased line/cable slip link config using slattach.
- Corrected a minor PLIP stoopidity I inflicted that fortunately noone
- appears to have noticed.
- Ammended Slip Server config to run a script in lieu of 'dip -i'
- Fixed numerous tyops and mizpellinks (When will I not ?)
-
-